Generator reference photo · supplied equipment to confirm
20–400kVASelected reference range
Stage V options45kVA and 60kVA references
One local contactEnquire with Hire & Safety UK
MATCH THE POWER TO THE JOB
Choose your generator range.
Browse selected generator options available to enquire about through Hire and Safety UK and our supply partners. These are supplier reference configurations, rather than confirmed depot stock. Our team will confirm the generator, suitability, availability and complete hire package.
Reference photo · supplied model may vary
Canopy · 20kVA
20kVA diesel generator
Enclosed diesel generator option for temporary site power. Tell us your equipment and operating hours so we can confirm a suitable package.
20 kVA class730 kg reference
View technical specifications
Reference model
XD
Dimensions (L × W × H)
1,685 × 950 × 1,485 mm
Reference dry weight*
730 kg
Fuel tank
45 litres
Fuel use at 50% / 75% / 100% load
2.9 / 3.9 / 5.3 litres/hour
Sound pressure
62.6 dB(A) at 7m, 75% load
Voltage / sockets
Confirm voltage, phase and connections
Emissions class
To confirm for supplied unit
*Supplier reference weight includes lubricating oil, with no coolant or fuel. Dimensions, fuel use and noise apply to the reference configuration. Confirm the supplied set and operating conditions.
Enclosed diesel generator option for temporary site power. Tell us your equipment and operating hours so we can confirm a suitable package.
30 kVA class1,002 kg reference
View technical specifications
Reference model
P33
Dimensions (L × W × H)
2,102 × 970 × 1,630 mm
Reference dry weight*
1,002 kg
Fuel tank
161 litres
Fuel use at 50% / 75% / 100% load
4 / 5.7 / 7.4 litres/hour
Sound pressure
65 dB(A) at 7m, 75% load
Voltage / sockets
Confirm voltage, phase and connections
Emissions class
To confirm for supplied unit
*Supplier reference weight includes lubricating oil, with no coolant or fuel. Dimensions, fuel use and noise apply to the reference configuration. Confirm the supplied set and operating conditions.
Stage V reference option for projects with an emissions requirement. Tell us your equipment and operating hours so we can confirm a suitable package.
45 kVA class987 kg reference
View technical specifications
Reference model
GPW45Y
Dimensions (L × W × H)
2,200 × 1,020 × 1,620 mm
Reference dry weight*
987 kg
Fuel tank
245 litres
Fuel use at 50% / 75% / 100% load
5.2 / 7.43 / 10.55 litres/hour
Sound pressure
61 dB(A) at 7m; test load not specified
Voltage / sockets
400/230V; connections to confirm
Emissions class
Stage V reference model; supplied unit to confirm
*Supplier reference weight includes lubricating oil, with no coolant or fuel. Dimensions, fuel use and noise apply to the reference configuration. Confirm the supplied set and operating conditions.
Stage V reference option for projects with an emissions requirement. Tell us your equipment and operating hours so we can confirm a suitable package.
60 kVA class1,250 kg reference
View technical specifications
Reference model
GPW60I/FS5
Dimensions (L × W × H)
2,402 × 1,033 × 1,830 mm
Reference dry weight*
1,250 kg
Fuel tank
300 litres
Fuel use at 50% / 75% / 100% load
6.9 / 10.31 / 13.86 litres/hour
Sound pressure
64 dB(A) at 7m; test load not specified
Voltage / sockets
400/230V; connections to confirm
Emissions class
Stage V reference model; supplied unit to confirm
*Supplier reference weight includes lubricating oil, with no coolant or fuel. Dimensions, fuel use and noise apply to the reference configuration. Confirm the supplied set and operating conditions.
Enclosed diesel generator option for temporary site power. Tell us your equipment and operating hours so we can confirm a suitable package.
65 kVA class1,319 kg reference
View technical specifications
Reference model
P65
Dimensions (L × W × H)
2,300 × 1,120 × 1,630 mm
Reference dry weight*
1,319 kg
Fuel tank
219 litres
Fuel use at 50% / 75% / 100% load
7.8 / 12.3 / 16.3 litres/hour
Sound pressure
64 dB(A) at 7m, 75% load
Voltage / sockets
Confirm voltage, phase and connections
Emissions class
To confirm for supplied unit
*Supplier reference weight includes lubricating oil, with no coolant or fuel. Dimensions, fuel use and noise apply to the reference configuration. Confirm the supplied set and operating conditions.
Enclosed diesel generator option for temporary site power. Tell us your equipment and operating hours so we can confirm a suitable package.
100 kVA class1,744 kg reference
View technical specifications
Reference model
P110
Dimensions (L × W × H)
2,770 × 1,120 × 1,630 mm
Reference dry weight*
1,744 kg
Fuel tank
250 litres
Fuel use at 50% / 75% / 100% load
12.9 / 18.9 / 23.8 litres/hour
Sound pressure
67 dB(A) at 7m, 75% load
Voltage / sockets
Confirm voltage, phase and connections
Emissions class
To confirm for supplied unit
*Supplier reference weight includes lubricating oil, with no coolant or fuel. Dimensions, fuel use and noise apply to the reference configuration. Confirm the supplied set and operating conditions.
Enclosed diesel generator option for temporary site power. Tell us your equipment and operating hours so we can confirm a suitable package.
150 kVA class2,158 kg reference
View technical specifications
Reference model
P165
Dimensions (L × W × H)
3,520 × 1,120 × 1,920 mm
Reference dry weight*
2,158 kg
Fuel tank
349 litres
Fuel use at 50% / 75% / 100% load
19.9 / 28.1 / 33.5 litres/hour
Sound pressure
65 dB(A) at 7m, 75% load
Voltage / sockets
Confirm voltage, phase and connections
Emissions class
To confirm for supplied unit
*Supplier reference weight includes lubricating oil, with no coolant or fuel. Dimensions, fuel use and noise apply to the reference configuration. Confirm the supplied set and operating conditions.
Enclosed diesel generator option for temporary site power. Tell us your equipment and operating hours so we can confirm a suitable package.
200 kVA class2,944 kg reference
View technical specifications
Reference model
P220
Dimensions (L × W × H)
3,894 × 1,300 × 2,101 mm
Reference dry weight*
2,944 kg
Fuel tank
550 / 1,480 (variant dependent) litres
Fuel use at 50% / 75% / 100% load
26.8 / 37.6 / 48.7 litres/hour
Sound pressure
68 dB(A) at 7m, 75% load
Voltage / sockets
Confirm voltage, phase and connections
Emissions class
To confirm for supplied unit
*Supplier reference weight includes lubricating oil, with no coolant or fuel. Dimensions, fuel use and noise apply to the reference configuration. Confirm the supplied set and operating conditions.
Enclosed diesel generator option for temporary site power. Tell us your equipment and operating hours so we can confirm a suitable package.
275 kVA class3,880 kg reference
View technical specifications
Reference model
PRO
Dimensions (L × W × H)
4,065 × 1,400 × 2,124 mm
Reference dry weight*
3,880 kg
Fuel tank
637 litres
Fuel use at 50% / 75% / 100% load
33.8 / 47.3 / 62.5 litres/hour
Sound pressure
66.3 dB(A) at 7m, 75% load
Voltage / sockets
Confirm voltage, phase and connections
Emissions class
To confirm for supplied unit
*Supplier reference weight includes lubricating oil, with no coolant or fuel. Dimensions, fuel use and noise apply to the reference configuration. Confirm the supplied set and operating conditions.
Enclosed diesel generator option for temporary site power. Tell us your equipment and operating hours so we can confirm a suitable package.
400 kVA class4,655 kg reference
View technical specifications
Reference model
P400
Dimensions (L × W × H)
4,930 × 1,658 × 2,422 mm
Reference dry weight*
4,655 kg
Fuel tank
887 litres
Fuel use at 50% / 75% / 100% load
36.2 / 53 / 69.6 litres/hour
Sound pressure
69 dB(A) at 7m, 75% load
Voltage / sockets
Confirm voltage, phase and connections
Emissions class
To confirm for supplied unit
*Supplier reference weight includes lubricating oil, with no coolant or fuel. Dimensions, fuel use and noise apply to the reference configuration. Confirm the supplied set and operating conditions.
No generators match these filters. Choose another range or ask our team for help.
About the specifications
Reference information checked against supplier literature on 11 November 2026. Photographs may show supplier or manufacturer markings. The hire service and your enquiry are handled by Hire and Safety UK. Actual models, ratings, emissions class, tank options, dimensions and performance must be confirmed before hire.
MORE THAN THE GENERATOR
Tell us what your site needs.
Cables & distribution
Ask about distribution boards, cable lengths and suitable connections for your equipment.
Fuel & run time
Share your working hours and refuelling access. Ask about external tanks and fuel arrangements.
Delivery & positioning
Confirm access, unloading, installation and commissioning requirements with the team.
Specialist power enquiries
Need a larger set, a towable or secure unit, or a hybrid system? Ask us to check options with our supply partners.
Accessories and specialist services are quoted to suit the project and are subject to confirmation.
Send the equipment list, power ratings or nameplate photos, site postcode, required dates and operating hours. Include motor starting loads, noise limits, emissions requirements and any essential loads. We will help arrange the next step to confirm a suitable set.